Determination of blood pressure in newborns <b>[Abstract in English]</b>

Authors

  • Manoel Antonio da Silva Ribeiro PUCRS
  • Pedro Celiny Ramos Garcia PUCRS
  • Renato Machado Fiori PUCRS

Keywords:

Hipotensão, Hipertensão, recém nascido de baixo peso, recém-nascido prematuro.

Abstract

Objective: To describe the recommendations for the determination of the blood pressure in newborn, the methods and the devices. Sources of data: Review of medical articles about blood pressure in newborn published in the last twenty years (database: Medline, PubMed) and original articles about the flush method. Summary of the findings: Several factors complicate the measures and interpretation of the blood pressure in newborns, like variable size of the upper arm, difficulty in tearful newborn and variation in the blood pressure regarding the weight and gestational age. The measure of the blood pressure should be performed preferentially in the right upper arm, with cuff size corresponding to 40% of the circumference of the upper arm and that involves 80% to 100% of the respective extremity. Nowadays, noninvasive measurements methods of the blood pressure feel well spread, especially the use of oscillometric automatic. Moreover, the antique flush method and pulse oximetry techniques have been being cited in the literature. Like more important limitation to meets itself the validation absence of the devices in neonatology, especially in the oscillometrics devices. Conclusions: Two important elements for obtainment of exact blood pressures are a calm baby and a adequate cuff size and all described methods are adequate for measurement of the blood pressure. KEY WORDS: BLOOD PRESSURE DETERMINATION/ methods; BLOOD PRESSURE DETERMINATION/instrumentation; INFANT, NEWBORN; HYPOTENSION; HYPERTENSION INFANT NEWBORN; PREMATURE.

Downloads

Download data is not yet available.

Author Biographies

Manoel Antonio da Silva Ribeiro, PUCRS

Neonatologista do Hospital São Lucas da PUCRS. Mestrando do Curso de Pós-graduação em Medicina/Pediatria e Saúde da Criança da Pontifícia Universidade Católica do Rio Grande do Sul.

Pedro Celiny Ramos Garcia, PUCRS

Professor Adjunto Doutor do Departamento de Pediatria da Faculdade de Medicina da PUCRS. Regente da Disciplina de Disfunção Orgânica na Criança do Curso de Pós-graduação em Medicina/Pediatria e Saúde da Criança da PUCRS. Chefe do Serviço de Pediatria Intensiva do Hospital São Lucas da PUCRS.

Renato Machado Fiori, PUCRS

Professor Titular do Departamento de Pediatria da Faculdade de Medicina da PUCRS. Chefe do Serviço de Neonatologia o Hospital São Lucas da PUCRS. Coordenador do Curso de Pós-graduação em Medicina/Pediatria e Saúde da Criança da PUCRS. Chefe do Serviço de Pediatria Intensiva do Hospital São Lucas da PUCRS.

Published

2007-10-01

How to Cite

Ribeiro, M. A. da S., Garcia, P. C. R., & Fiori, R. M. (2007). Determination of blood pressure in newborns <b>[Abstract in English]</b>. Scientia Medica, 17(3), 168–170. Retrieved from https://revistaseletronicas.pucrs.br/ojs/index.php/scientiamedica/article/view/1665