OBJECTIVE: This in vitro study aimed to evaluate preparation time, wear, transportation, and centering ability of two manual instruments, namely Flexofile and Prodesign® M, in curved root canal preparation.
METHODS: Forty mesiobuccal and mesiolingual canals of the first or second lower molars were used, with standard length, degree, and radius of curvature among all samples. The canals were randomly divided into two experimental groups (n=20) according to the preparation instrument analyzed. The preparations were performed by a single operator. The preparation time was controlled, and the values obtained were analyzed. To verify the wear, transportation, and centering ability of the instruments, tomography images were taken before and after instrumentation. The analysis was performed using axial sections previously identified at 2 mm below the tooth apex with the aid of the OnDemand3DTM Dental program. For statistical analysis, Student’s t-test was used, with a significance level of 5%.
RESULTS: The time required to prepare root canals was lesser using Prodesign® M instruments than using Flexofile instruments. Regarding tooth wear, no statistical difference was observed. However, Flexofile instruments had a low centralization capacity in root canal preparation, and there is a trend of transport in the mesial direction of the root canal.
CONCLUSION: Although no statistical difference was observed between the two instruments, the Prodesign® M instruments had a better cantering ability in the preparation. As well as, the time required to prepare the root canals was inferior when Prodesign® M was used.
*** Análise do tempo de execução, desgaste e centralização no preparo de canais radiculares curvos realizados com instrumentos manuais Flexofile e Prodesign® M ***
OBJETIVO: Este estudo tem como objetivo avaliar, in vitro, o tempo de execução, desgaste, transporte e a centricidade no preparo de canais radiculares curvos com dois tipos de instrumentos manuais: Flexofile e Prodesign® M.
METODOLOGIA: Foram utilizados quarenta canais mésio-vestibulares e mésio-linguais de primeiros ou segundos molares inferiores, com comprimento, grau e raio de curvatura padronizados entre todas as amostras. Os canais foram divididos aleatoriamente em dois grupos experimentais (n=20), conforme o instrumento de preparo a ser testado. Os preparos foram feitos por um único operador. O tempo para execução do preparo foi cronometrado e os valores obtidos foram analisados. Para verificação do desgaste, centricidade e ocorrência de transporte no preparo, foram realizadas imagens tomográficas, antes e após a realização das instrumentações. A análise foi feita em cortes axiais previamente identificados a 2 mm aquém do ápice dentário, com auxílio do programa OsiriX® Imaging. Para análise estatística, foi utilizado o Teste t de Student, com nível de significância de 5%.
RESULTADOS: O tempo para execução do preparo dos canais radiculares com instrumentos Prodesign® M foi menor do que em relação aos instrumentos Flexofile. Com relação ao desgaste dentinário, não foi observada diferença estatística. Entretanto, os instrumentos Flexofile apresentaram menor capacidade de centralização durante o preparo, havendo uma tendência de transporte no sentido mesial do canal radicular.
CONCLUSÃO: Apesar de não haver diferença estatística entre os instrumentos avaliados, o Prodesign® M apresentou uma melhor capacidade de centralização durante o peparo. Além disso, o tempo de preparo durante o seu uso foi inferior.
Palavras-chave: endodontia; instrumentos odontológicos; preparo de canal radicular; tomografia computadorizada de feixe cônico.
Referências
Schilder H. Cleaning and shaping the root canal. Dent Clin North Am 1974;18(2):269-96.
Leonardi DP, Haragushiku GA, Tomazinho FS, Furuse AY, Volpato L, Baratto-Filho F. Undergraduate students introduction to manual and Rotary root canal instrumentation. Bull Tokyo Dent Coll 2012;53(3):155-9.
https://doi.org/10.2209/tdcpublication.53.155
Iqbal MK, Maggiore F, Suh B, Edwards KR, Kang J, Kim S. Comparison of apical transportation in four Ni-Ti rotary instrumentation technique. J Endod 2003;29(9):587-91.
https://doi.org/10.1097/00004770-200309000-00011
Boff LB, Cord CB, Galafassi D, Melo TAF. Análise do desvio apical promovido por três tipos de sistemas endodônticos: manual, rotatório e reciprocante. Dent Press Endod 2015;5(2):40-44.
https://doi.org/10.14436/2358-2545.5.2.040-044.oar
Pettiette MT, Metzger Z, Phillips C, Trope M. Endodontic complications of root canal therapy performed by dental students with stainless-steel K-files and nickel-titanium hand files. J Endod 1999;25(4):230-34.
https://doi.org/10.1016/S0099-2399(99)80148-4
Pettiette MT, Delano EO, Trope M. Evaluation of success rate of endodontic treatment performed by students with stainless-steel K-files and nickel-titanium hand files. J Endod 2001;27(2):124-7.
https://doi.org/10.1097/00004770-200102000-00017
Tu MG, Chen SY, Huang HL, Tsai CC. Endodontic shaping performance using nickel-titamium hand and motor ProTaper systems by novice dental students. J Formos Med Assoc 2008;107(5):381-8.
https://doi.org/10.1016/S0929-6646(08)60103-5
Capar ID, Ertas H, Arslan H. Comparison of cyclic fatigue resistance of nickel-titanium coronal flaring instruments. J Endod 2014;40(8):1182-5.
https://doi.org/10.1016/j.joen.2013.12.031
Kwak SW, Cheung GS, Ha JH, Kim SK, Lee H, Kim HC. Preference of undergraduate students after first experience on nickel titanium endodonticinstruments. Restor Dent Endod 2016;41(3):176-81.
https://doi.org/10.5395/rde.2016.41.3.176
Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol 1971;32(2):271-5.
https://doi.org/10.1016/0030-4220(71)90230-1
Gambill JM, Alder M, del Rio CE. Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomography. J Endod 1996;22(7):369-75. https://doi.org/10.1016/S0099-2399(96) 80221-4
Kandaswamy D, Venkateshbabu N, Porkodi I, Pradeep G. Canal-centering ability: An endodontic challenge. J Conserv Dent 2009;12(1):3-9.
https://doi.org/10.4103/0972-0707.53334
McRay B, Cox TC, Cohenca N, Johnson JD, Paranjpe A. A microcomputed tomography-based comparison of the canal transportation and centeringability of ProTaper Universal rotary and WaveOne reciprocating files. Quintessence Int 2014;45(2):101-8.
Coelho MS, Fontana CE, Kato AS, de Martin AS, da Silveira Bueno CE. Effects of Glide Path on the Centering Ability and Preparation Time of Two Reciprocating Instruments. Iran Endod J 2016;11(1):33-7.
Shah DY, Wadekar SI, Dadpe AM, Jadhav GR, Choudhary LJ, Kalra DD. Canal transportation and centering ability of protaper and self-adjusting file system in long oval canals: An ex-vivo cone-beam computed tomography analysis. J Conserv Dent 2017;20(2):105-109.
https://doi.org/10.4103/0972-0707.212234
Shenoi PR, Luniya DA, Badole GP, Makade CS, Kubde R, Khode RT. Comparative evaluation of shaping ability of V-Taper 2H, ProTaper Next, and HyFlex CM in curved canals using cone-beam computed tomography: An in vitro study. Indian J Dent Res 2017;28(2):181-186.
https://doi.org/10.4103/ijdr.IJDR_34_16
Mamede-Neto I, Borges AH, Guedes OA, de Oliveira D, Pedro FL, Estrela C. Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography. Open Dent J 2017;11:71-78.
ttps://doi.org/10.2174/1874210601711010071
Glosson CR, Haller RH, Dove SB, del Rio CE. A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments. J Endod 1995;21(3):146-51.
https://doi.org/10.1016/S0099-2399(06)80441-3
Short JA, Morgan LA, Baumgartner JC. A comparison of canal centering ability of four instrumentation techniques. J Endod 1997;23(8):503-7.
https://doi.org/10.1016/S0099-2399(97)80310-X
Elliott LM, Curtis RV, Pitt Ford TR. Cutting pattern of nickel-titanium files using two preparation techniques. Endod Dent Traumatol 1998;14(1):10-5.
https://doi.org/10.1111/j.1600-9657.1998.tb00802.x
Schäfer E, Florek H. Efficiency of rotary nickel-titanium K3 instruments compared with stainless steel hand K-Flexofile. Part 1. Shaping ability in simulated curved canals. Int Endod J 2003;36(3):199-207.
https://doi.org/10.1046/j.1365-2591.2003.00643.x
Stavileci M, Hoxha V, Görduysus Ö, Tatar I, Laperre K, Hostens J, Küçükkaya S, Berisha M. Effects of preparation techniques on root canal shaping assessed by micro-computed tomography. Med Sci Monit Basic Res 2013;19:163-8.
https://doi.org/10.12659/MSMBR.889350
Wildey WL, Senia ES, Montgomery S. Another look at root canal instrumentation. Oral Surg Oral Med Oral Pathol 1992;74(4):499-507.
https://doi.org/10.1016/0030-4220(92)90303-8
Abou-Rass M, Frank AL, Glick DH. The anticurvature filing method to prepare the curved root canal. J Am Dent Assoc 1980;101(5):792-4.
https://doi.org/10.14219/jada.archive.1980.0427
Peters OA. Current challenges and concepts in the preparation of root canal systems: a review. J Endod 2004;30(8):559-67.
https://doi.org/10.1097/01.DON.0000129039.59003.9D
Wu MK, Fan B, Wesselink PR: Leakage along apical root fillings in curved root canals. Part I: effects of apical transportation on seal of root. J Endod 2000;26(4):210-16.
Downloads
Publicado
Edição
Seção
Licença
DIREITOS AUTORAIS
A submissão de originais para a Odonto Ciência implica na transferência, pelos autores, dos direitos de publicação. Os direitos autorais para os artigos publicados nesta revista são do autor, com direitos da revista sobre a primeira publicação. Os autores somente poderão utilizar os mesmos resultados em outras publicações indicando claramente a Odonto Ciência como o meio da publicação original.
LICENÇA CREATIVE COMMONS
Em virtude de ser uma revista de acesso aberto, permite-se o uso gratuito dos artigos em aplicações científicas e educacionais, desde que citada a fonte. De acordo com a Licença Creative Commons CC-BY 4.0, adotada pela Odonto Ciência o usuário deve respeitar os requisitos abaixo.
Você tem o direito de:
Compartilhar — copiar e redistribuir o material em qualquer suporte ou formato.
Adaptar — remixar, transformar e criar a partir do material para qualquer fim, mesmo que comercialmente.
Porém, somente de acordo com os termos seguintes:
Atribuição — Você deve dar o crédito apropriado, prover um link para a licença e indicar se mudanças foram feitas. Você deve fazê-lo em qualquer circunstância razoável, mas de maneira alguma que sugira que a Odonto Ciência apoia você ou o seu uso.
Sem restrições adicionais — Você não pode aplicar termos jurídicos ou medidas de caráter tecnológico que restrinjam legalmente outros de fazerem algo que a licença permita.
Avisos:
Você não tem de cumprir com os termos da licença relativamente a elementos do material que estejam no domínio público ou cuja utilização seja permitida por uma exceção ou limitação que seja aplicável.
Não são dadas quaisquer garantias. A licença pode não lhe dar todas as autorizações necessárias para o uso pretendido. Por exemplo, outros direitos, tais como direitos de imagem, de privacidade ou direitos morais, podem limitar o uso do material.
Para mais detalhes sobre a licença Creative Commons, siga o link no rodapé desta página eletrônica.