Reciprocating versus Rotary instruments: a review

Authors

  • Flavia Villela Laurindo Pontifícia Universidade Católica do Rio Grande do Sul
  • José Antonio Poli de Figueiredo Pontifícia Universidade Católica do Rio Grande do Sul

DOI:

https://doi.org/10.15448/1980-6523.2016.3.20917

Keywords:

Reciprocating systems, Rotational systems, Endodontics

Abstract

Objective: Literature started to point out essential parameters involving reciprocating instruments through clinical and laboratory essays. Looking into apical debris extrusion, incidence of instrument breakage, canal centering ability, apical zipping, a myriad of information has become available. The aim of this review is to revisit the literature and compare reciprocal and continuous rotation techniques.
Methods: A review of current literature may collect recent findings.
Conclusion: Reciprocating systems are similar in some aspects in comparison to rotational systems, with regards to cleaning ability, centered preparations, cleaning ability, reduction of Enterococcus faecalis and dentine defects. On the other hand, being single use and enhanced resistance to fatigue, together with novel methods to treat the alloy may lead to the thought that reciprocal systems are an excellent aid to root canal preparation. However, more needs to be understood about this new era of instruments to verify, long term and especially in vivo, the success and failure when these instruments are used.

References

Schäfer E, Schulz-Bongert U, Tulus G. Comparison of hand stainless steel and nickel titanium rotary instrumentation: a clinical study. J Endod 2004;30:432-5. https://doi.org/10.1097/00004770-200406000-00014

Haikel Y, Serfaty R, Bateman G, Senger B, Alleman C. Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments. J Endod 1999;25:434-440. https://doi.org/10.1016/S0099-2399(99)80274-X

Parashos P, Messer HH. Rotary NiTi instrument fracture and its consequences. J Endod 2006;32:1031-1043. https://doi.org/10.1016/j. joen.2006.06.008

Haapasalo M, Shen Y. Evolution of nickel-titanium instruments: from past to future. Endod Topics 2013;29:3-17. https://doi.org/10.1111/etp.12049

Yared G. Canal preparation using only one Ni-Ti Rotary instrument: preliminary observations. Int Endod J 2008;41:339-344. https://doi. org/10.1111/j.1365-2591.2007.01351.x

Paque F, Zehnder M, De-Deus G. Microtomography based comparison of reciprocating single-file F2 ProTaper technique versus rotary full sequence. J Endod 2011;37:1394-1397. https://doi.org/10.1016/j.joen.2011.06.031

You S, Kim H, Bae K, Back S, Kum K, Lee W. Shaping ability of reciprocating motion in curved root canals: Acomparative study with Mico-computed tomography. J Endod 2011;37:1296-1300. https://doi.org/10.1016/j.joen.2011.05.021

Franco V, Fabiani C, Taschieri S, Malentacca A, Bortolin M, Fabbro MD. Investigation on the shaping ability of nickel-titanium files when used with a reciprocating motion. J Endod 2011;10:1398-401. https://doi. org/10.1016/j.joen.2011.06.030

Bürklein S, Hinschitza K, Dammaschke T, Schäfer E. Shapingablity and cleaning effectiveness of two single-file systems I severely curved root canals of extracted teeth:Reciproc and WaveOne versus Mtwo and ProTaper. Int Endod J 2012;45:449-61. https://doi.org/10.1111/j.1365-

2011.01996.x

Marzouk AM, Ghoneim AG. Computed Tomographic evaluation osf canal shape instrumented by different kinematics rotary nickel-titanium systems. J Endod 2013;39:906-9. https://doi.org/10.1016/j.joen.2013.04.023

Bürklein S, Benten S, Schäfee E. Shaping ability of different single-file systems in severely curved root canals of extracted teeth. Int Endod J.2013;46:590-7. https://doi.org/10.1111/iej.12037

Berutti E, Chiandussi G, Paolino DS, Scotti N, Cantatore G, Castellucci A, Pasqualini D. Canal shaping with WaveOne primary Reciprocating files and Pro Taper System: A Comparative study. J Endod 2012;38:505-9.

https://doi.org/10.1016/j.joen.2011.12.040

Robinson JP, Lumley PJ, Cooper PR, Grover LM, Walmsley AD. Reciprocating root canal techinique induces greater debris accumulation than a continuous rotary techinique as assessed by 3-dimensional Micro-computed tomography. J Endod 2013;39:1067-70. https://doi. org/10.1016/j.joen.2013.04.003

De-Deus G, Barino B, Zamolyi RQ, et al. Suboptimal debridement quality produced by the single-file F2 ProTaper techinique in oval-shaped canals. J Endod 2010;36:1897-900. https://doi.org/10.1016/j.joen.2010.08.009

Al-Omari MA, Dummer PM. Canal blockage and debris extrusion with eight preparation techiniques. J Endod 1995;21:154-8. https://doi.org/10.1016/ S0099-2399(06)80443-7

Bürklein S, Schafer E. Apically extrude debris with reciprocating singlefile

and full-sequence rotary instrumentation systems. J Endod 2012;38: 850-2. https://doi.org/10.1016/j.joen.2012.02.017

Tinoco JM, De-Deus G, Tinoco EMB, Saavedra F, Fidel RAS, Sassone LM. Apical extrusion of bacteria when using reciprocating single-file and rotary multfile instrumentation systems. Int Endod J. 2014;47(6):560-6. https:// doi.org/ 10.1111/iej.12187.

Koçak S, Koçak MM, Saglam BC, Türker SA, Sagsen B, Er Ö. Apical extrusion of debris using self-adjusting file, reciprocating single-file, and 2 rotary instrumentation systems. J Endod. 2013;39:1278-80. https://doi. org/10.1016/j.joen.2013.06.013

Stuart CH, Scwartz SA, Beeson TJ, Owatz CB. Enterococcus faecalis:Its Role in root canal treatment failure and current concepts in retreatment. J Endod 2006;32[2]:93-8. https://doi.org/10.1016/j.joen.2005.10.049

Ferrer-Luque CM, Bejarano I, Ruiz-Linares M, Baca P. Reduction in Enteroccocus faecalis counts – a comparison between Rotary and reciprocating systems. Int Endod J. 2014;47:380-6. https://doi. org/10.1111/iej.12158

Machado ME, Nabeshima CK, Leonardo MF, et al. Influence of reciprocating single file and Rotary instrumentation on bacterial reduction on infected root canals. Int Endod J 2013;46:1083-7. https://doi.org/10.1111/iej.12108

Martinho FC, Gomes APM, Fernandes AMM, Ferreira NS, Endo MS, Freitas LF, Camões ICG. Clinical comparision of the effectiveness of single-file reciprocating systems and rotary systems for removal of endotoxins and cultivable bacterial from primarily infected root canals. J Endod 2014;40:625-9. https://doi.org/10.1016/j.joen.2013.12.006

Alves FRF, Rôças IN, Almeida BM, Neves MAS, Zoffoli J, Siqueira Jr. JF. Quantitative molecular and culture analyses of bacterial elimination in ovalshaped root canals by a single-file instrumentation technique. Int Endod J 2012;45:871-7. https://doi.org/10.1111/j.1365-2591.2012.02045.x

Câmara AC, Aguiar CM, Figueiredo JAP. Assesment of deviation after biomechanical preparation of the coronal, middle and apical thirds of root canals instrumented with three hero rotary systems. J Endod 2007;33:1460-3. https://doi.org/10.1016/j.joen.2007.07.029

Brkanic T, Stojsin I, Zivkovic S, Vukoje K. Canal wall thickness after preparation with NiTi rotary files. Microscopy Research and Techinique 2012;75:253-57. https://doi.org/10.1002/jemt.21049

Stern S, Patel S, Foschi F, Sherriff M, Mannocci F. Changes in centring and shaping ability using three nickel-titanium instrumentation techniques analysed by micro-computed tomography. Int Endod J 2012;45:514-23. https://doi.org/10.1111/j.1365-2591.2011.02004.x

Gergi R, Arbab-Chirani R, Osta N, Naaman A. Micro-computed tomographic avaluation of canal transportation instrumented by different kinematics rotary nickel-titanium instruments. J Endod 2014;40:1223-7. https://doi.org/10.1016/j.joen.2014.01.039

Gergi R, Osta N, Bourbouze G, Zgheib C, Arab-Chirani R, Naaman A. Effects of three nickel titanium instrument systems on root canal geometry assessed by micro-computed tomography. Int Endod J 2015;48:162-70. https://doi.org/10.1111/iej.12296

NazariMoghadam K, Shahab S, Rostami G. Canal transportation and centering ability of twisted file and reciproc: a cone-beam computed tomography assessment. Iran Endod J 2014:9:174-9.

Hwang YH, Bae KS, Baek SH, Kum KY, Lee W, Shon WJ, Chang SW. Shaping ability of the conventional nickel-titanium and reciprocating nickel-titanium file systems: a comparative study using micro-computed tomography. J Endod 2014;40:1186-9. https://doi.org/10.1016/j. joen.2013.12.032

Nabavizadeh M, Abbaszadegan A, Khojastepour L, Amirhosseini M, Kiani E. A comparison of apical transportation in severely curved canals induced by reciproc and biorace systems. Iran Endod J 2014;9:117-22.

Capar ID, Ertas H, Ok E, Arslan H, Ertas ET. Comparative study of different novel nickel-titanium rotary systems for root canal preparation in severely curved root canals. J Endod 2014:40:852-6. https://doi.org/10.1016/j.joen.2013.10.010

Saber SE, Nagy MM, Schäfer E. Comparative evaluation of the shaping ability of WaveOne, Reciproc and OneShapes single-file systems in severely curved root canals of extracted teeth. Int Endod J 2015;48: 109-14. https://doi.org/10.1111/iej.12289

Goldberg M, Dahan S, Machtou P. Centering ability and influence of experience when using WaveOne single-file technique in simulated canals. Int J Dent 2012. https://doi.org/10.1155/2012/206321

Muñoz E, Forner L, Llena C. Influence of operator`s experience on root canal shaping ability with a rotary nickel-titanium single-file reciprocating motion system. J Endod 2014;40:547-50.https://doi.org/10.1016/j.joen.2013.08.027

Bier CA, Shemesh H, Tanomaru-Filho M, Wesselink PR, Wu Mk. The ability of different nickel-titanium Rotary instruments to induce dentinal damage during canal preparation. J Endod 2009;35:236-8. https://doi.org/10.1016/j.joen.2008.10.021

Kim HC, Lee MH, Yum J, Versluis A, Lee CJ, Kim BM. Potential relationship

between design of nickel-titanium Rotary instruments and vertical root fracture. J Endod 2010;36:1195-9. https://doi.org/10.1016/j.joen.2010.02.010

Bürklein S, Tsotsis P, Schafer E. Incidence of dentinal defects after root anal preparation:reciprocating versus rotary instrumentation. J Endod 2013;39:501-4. https://doi.org/10.1016/j.joen.2012.11.045

Nasr HMAE, Kader KGAE. Dentinal damage and fracture resistance of oval roots prepared with single-file systems using different kinematics. J Endod 2014;40:849-51. https://doi.org/10.1016/j.joen.2013.09.020

Ashwinkumar V. Krithikadatta J, Surendran S, Velmurugan N. Effect of reciprocating file motion on microcrack formation in root canals: an SEM study. Int Endod J 2014;47:622-7. https://doi.org/10.1111/iej.12197

Haikel Y, Serfaty R, Batemann G, Senger B, Allemann C. Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments. J Endod 1999;25:434-40. https://doi.org/10.1016/S0099-

(99)80274-X

Parashos P, Gordon I, Messer HH. Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use. J Endod 2004;30:722-5. https://doi.org/10.1097/01.DON.0000129963.42882.C9

Kuhn G, Tavernier B, Jordan L. Influence of structure on nickel-titanium endodontic instrument failure. J Endod 2001;27:516-20. https://doi.org/10.1097/00004770-200108000-00005

Kuhn G, Jordan L. Fatigue and mechanical properties of nickeltitanium endodontic instruments. J Endod 2002;28:716-20. https://doi.org/10.1097/00004770-200210000-00009

Hayashi Y, Yoneyama T, Yahata Y, et al. Phase transformation behavior and bending properties of hybrid nickel-titanium rotary endodontic instruments. Int Endod J 2007;40:247-53.

https://doi.org/10.1111/j.1365-2591.2007.01203.x

Yahata Y, Yoneyama T, Hayashi Y et al. Effect of heat treatment on transformation temperatures and bending properties of nickel-titanium endodontic instruments. Int Endod J 2009;42:621-6. https://doi.org/10.1111/j.1365-2591.2009.01563.x

Shen Y, Zhou H, Zhen Y, Peng B, Haapasalo M. Current Challenges and concepts of the thermomechanical treatment of nickel-titanium instruments. J Endod 2013;39:163-72. https://doi.org/10.1016/j. joen.2012.11.005

Santos M, Gavini G, Siqueira EL, Costa C. Effect of nitrogen ion impantation on the flexibility of rotary nickel-titanium instruments. J Endod. 2012;38:673-5. https://doi.org/10.1016/j.joen.2012.01.012.

Gutmann JL, Gao Y. Alteration in the inherent metallic and surface properties of nickel-titanium root canal instruments to enhance performance, durability and safety: a focused review. Int Endod J 2012;45:113-28. https://doi.org/10.1111/j.1365-2591.2011.01957.x

Gambarini G, Grande MN, Plotino G, et al. Fatigue resistance of enginedriven rotary nickel-titanium instruments produced by new manufacturing methods. J Endod 2008;34:1003-5. https://doi.org/10.1016/j. joen.2008.05.007

Johnson E, Lloyd A, Kuttler S, Namerow K. Comparison between a novel nickel-titanium alloy and 508 nitinol on the cyclic fatigue life of Profile 25/04 rotary instruments. J Endod 2008;34:1406-9. https://doi.org/10.1016/j. joen.2008.07.029

Larsen CM, Watanabe I, Glickman GN, He J. Cyclic fatigue analysis of a new generation of nickel-titanium rotary instruments. J Endod 2009;35:401-3. https://doi.org/10.1016/j.joen.2008.12.010

Al-Hadlaq SMS, Al Jarbour FA, Al Thumairy RI. Evaluation of cyclic flexural fatigue of M-wire nickel-titanium rotary instruments. J Endod 2010;36: 305-7. https://doi.org/10.1016/j.joen.2009.10.032

Bouska J, Justman B, Williamson A, DeLong C, Qian F. Resistance to cyclic fatigue failure of a new endodontic rotary file. J Endod 2012;38:667- 9. https://doi.org/10.1016/j.joen.2012.01.016

Pérez-Higueras JJ, Arias A, Macorra JC. Cyclic fatigue resistence of K3, K3XF, and Twisted File nickel-titanium files under continuous rotation or reciprocating motion. J Endod. 2013;39:1585-8. https://doi.org/10.1016/j.joen.2013.07.020

De-Deus G, Moreira EJL, Lopes HP, Elias CN. Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement. Int Endod J 2010;43:1063-8. https://doi.org/10.1111/j.1365-2591.2010.01756.x

You S, Bae Y, Baek S, Kum K, Shon W, Lee W. Lifespan of one nickeltitanium rotary file with reciprocating motion in curved root canals. J Endod 2010;36:1991-4. https://doi.org/10.1016/j.joen.2010.08.040

Gambarini G, Gergi G, Naaman A, Osta N, Al Sudani D. Cyclic fatigue analysis of twisted file rotary NiTi instruments used in reciprocating motion. Int Endod J 2012;45:802-6. https://doi.org/10.1111/j.1365- 2591.2012.02036.x

Gavini G, Caldeira CL, Akisue E, Candeiro GTM, Kawakami AS. Resistence of flexural fatigue of reciproc R25 files under continuos rotation and reciprocating movement. J Endod 2012;38:684-7. https:// doi.org/10.1016/j.joen.2011.12.033

Plotino G, Grande NM, Testarelli L, Gambarini G. Cyclic fatigue of Reciproc an WaveOne reciprocating instruments. Int Endod J 2012;45:614-18.https://doi.org/10.1111/j.1365-2591.2012.02015.x

Arias A, Perez-Higueras JJ, Macorra JC. Differences in cyclic fatigue resistance at apical and coronal levels of Reciproc and WaveOne new files. J Endod 2012:38:1244-8. https://doi.org/10.1016/j.joen.2012.05.022

Pedullá E, Grande E, Plotino G, Gambarini G, Rapisarda E. Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel-titanium rotary instruments. J Endod 2013;39:258-61. https://doi.org/10.1016/j.joen.2012.10.025

Kim H, Kwak S, Cheung GS, Ko D, Chung S, Lee W. Cyclic fatigue and torsional resistance of two new nickel-titanium instruments used in reciprocation motion:Reciproc versus WaveOne. J Endod 2012;38: 541-4. https://doi.org/10.1016/j.joen.2011.11.014

Downloads

Published

2016-12-31

Issue

Section

Literature Review