Adequacy of the cuff during blood pressure measurement: an integrative review
DOI:
https://doi.org/10.15448/1983-652X.2015.1.19419Keywords:
Determination of blood pressure. Nursing. Blood pressure.Abstract
Objective: To identify scientific evidence available in the literature on the adequacy of the cuff during blood pressure (BP) measurement.
Materials and Methods: It is an integrative literature review. The databases accessed were LILACS, MEDLINE and BDENF. From the 39 articles found, 14 met the inclusion criteria and were selected.
Results: It was found that 64% of the studies were conducted by nurses and four (28%) by nurses and clinicians. There were few articles published on the subject of suitability of cuff during the measurement of blood pressure in Brazil in the last 13 years. Gaps in the knowledge of the health professionals involved with measurements of blood pressure reflects in the practice. Despite the offer of different cuffs, the majority of professionals did not measure the circumference of the patient’s arm. Standard size cuff with rubber bag of 12 × 23 cm were the only ones used. Studies have shown that the adequacy of the cuff is extremely important to obtain the correct values for BP measurements and to minimize the risk of false diagnoses.
Conclusions: Blood pressure measurement is not often being performed adequately and the measurement of patient’s arm
circumference one of the least performed procedures.
References
Alavarce DC, Pierin AMG. Development of educational hypermedia to teach an arterial blood pressure measurement procedure. Rev Esc Enferm USP [online]. 2011;45(4):939-44. http://dx.doi. org/10.1590/S0080-62342011000400021
Schmidt A, Filho AP, Maciel BC. Medida indireta da pressão arterial sistêmica. Medicina (Ribeirão Preto) [online]. 2004;37:240-5. http://dx.doi.org/10.11606/issn.2176-7262.v37i3/4p240-245
Galvão EL, Batista JG, Figueiredo FL, Pereira WF, Ferreira AE. Comparação entre os métodos auscultatório e oscilométrico de determinação da Pressão Arterial. Espaç Saúde 2009;10(2):27-33.
Rabello CCP, Pierin AMG, Mion JD. O conhecimento de profissionais da área da saúde sobre a medida da pressão arterial. Rev Esc Enferm USP [online]. 2004;38(2):127-34. http://dx.doi.org/10.1590/S0080- 62342004000200002
Veiga EV, Nogueira MS, Cárnio EC, Lavrador MAS, Moraes AS, Souza LAC, Lima NKC, Nobre F. Assessment of the techniques of blood pressure measurement by health professionals. Arq Bras Cardiol [online]. 2003;80(1). http://dx.doi.org/10.1590/S0066- 782X2003000100008
Ribeiro CCM, Lamas JLT. Comparação entre as técnicas de mensuração da pressão arterial em um e em dois tempos. Rev Bras Enferm [online]. 2012;65(4):630-6. http://dx.doi.org/10.1590/ S0034-71672012000400012
Veiga EV, Arcuri EAM, Cloutier L, Santos JLF. Blood pressure measurement: arm circumference and cuff size availability. Rev Latino-amo Enferm [online]. 2009;17(4).
Pickering TG, Salão JE, Appel LJ, Falkner BE, Graves J, Colina MN, Jones DW, Kurtz T, Sheps SG, Roccella EJ. Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Hypertension. 2005;45(1):142-61. http://dx.doi. org/10.1161/01.HYP.0000150859.47929.8e
Arcuri EAM, Araújo TL, Veiga EV, Oliveira SMJV, Lamas JLT, Santos JLF. Medida da pressão arterial e a produção científica de enfermeiros brasileiros. Rev Esc Enferm USP [online]. 2007 jun.;41(2):292-8. http://dx.doi.org/10.1590/S0080-62342007000200017
Brasil. Ministério da Saúde. Secretaria Executiva. Subsecretaria de Planejamento e Orçamento. Sistema de Planejamento do SUS: uma construção coletiva: Plano Nacional de Saúde (PNS) 2008/2009- 2011. Brasília (DF): Ministério da Saúde; 2010. 168 p.
Lamas JLT, Arcuri EAM, Brito CM, Cruz KCT. Registros intra-arteriais da pressão versus registros indiretos em função da largura do manguito. Rev Gaúcha Enferm [online]. 2006;27(4):599-609.
Silva SSBE, Colósimo FC, Pierin AMG. The effect of educational interventions on nursing team knowledge about arterial hypertension. Rev Esc Enferm USP [online]. 2010;44(2).
Polit DF, Beck CT, Hungler BP. Fundamentos de pesquisa em enfermagem: métodos, avaliação e utilização. 5ª ed. Porto Alegre:Artmed; 2004.
Broome ME. Integrative literature reviews for the development of concepts. In Rogers BL, Knalf KA. Concept development in nursing: foundations, techniques and applications. Philadelphia: W.B. Saunders Company; 2000. p. 231-50.
Silveira RCCP. O cuidado de enfermagem e o cateter de Hickman: a busca de evidências [dissertação]. Ribeirão Preto (SP): Universidade de São Paulo; 2005.
Ursi ES. Prevenção de lesões de pele no perioperatório revisão integrativa da literatura [dissertação]. Ribeirão Preto (SP): Universidade de São Paulo; 2005.
Almeida TCF, Lamas JLT. Nurses of adult intensive care unit: evaluation about direct and indirect blood pressure measurement. Rev. Esc Enferm USP [online]. 2013 June;47(2):369-76. http:// dx.doi.org/10.1590/S0080-62342013000200014
Freitas CCQ, Pantarotto RFR, Costa LRLG. Relação circunferência braquial e tamanho de manguitos utilizados nas Unidades Básicas de Saúde de uma cidade do interior paulista. J Health Sci Inst [online]. 2013;31(3):48-52.
Moreira MAD, Bernardino JR. Análise do conhecimento teórico/prático de profissionais da área de saúde sobre medida indireta da pressão arterial. Biosci J [online]. 2013; 29(1): 247-54.
Boll LFC, Irigoyen MC, Goldmeier S. Brazilian guidelines for arterial hypertension: the reality of nursing in a specialty hospital. Acta Paul Enferm [online]. 2012;25(5):775-80. http://dx.doi.org/10.1590/ S0103 21002012000500020
Ribeiro CCM, Lamas JLT. Comparação entre as técnicas de mensuração da pressão arterial em um e em dois tempos. Rev Bras Enferm [online]. 2012;65(4):630-6. http://dx.doi.org/10.1590/ S0034 71672012000400012
Reis RS, Lamas JLT. Uso de dispositivo automático de medida de pressão arterial em crianças entre 4 e 13 anos. Rev Eletr Enf [online]. 2009;11(4):794-800.
Aarcuri EAM, Rosa SCD, Scanavini RM, Denzin GSC. Arm and forearm blood pressure measurements as a functionof cuff width. Acta Paul Enferm [online]. 2009;22(1):37-42.
Aaraújo TL, Lopes MVO, Guedes NG, Cavalcante TF, Moreira RP, Chaves ES. Cuff dimension for children and adolescents: a study in a northeastern Brazilian city. Rev Latino-am Enfermagem [online]. 2008;16(5).
Spinella C, Lamas JLT. Fatores associados à hipertensão arterial e níveis pressóricos encontrados entre adolescentes trabalhadores. Rev Esc Enferm [online]. 2007;41(2).
Chaves EM, Gudes NG, Moreira RP, Cavalcante TF, Lima REF, Araújo TM. Manguitos de largura correta: levantamento em um grupo específico de crianças e adolescentes. Rev RENE [online]. 2004;5(2):35-40.
Pierin AMG, Geraldo AM. Validação dos aparelhos automáticos e semi-automáticos de medida da pressão arterial: uma revisão sobre o assunto. Rev Bras Hipertens. 2004;7(2):65-9.
Casti-eira MC, Gonzalez C, Rios MT, Moliner JR, Crespo J, Dominguez M. Sabemos tomar correctamente la pression arterial? Hiperten Riesgo Vasc. 2009;26(1):7-13. http://dx.doi.org/10.1016/ S1889 1837(09)70507-0
Cordella MP, Palotta L, Cesarino CB. Medida indireta da pressão arterial: um programa de educação continuada para a equipe de enfermagem em um hospital de ensino. Arq Ciênc Saúde [online]. 2005;12(1):21-6.
Downloads
Published
Issue
Section
License
COPYRIGHT
The submission of originals to Ciência & Saúde implies the transfer by the authors of the right for publication. Authors retain copyright and grant the journal right of first publication. If the authors wish to include the same data into another publication, they must cite Ciência & Saúde as the site of original publication.
CREATIVE COMMONS LICENSE
As this journal is open access, the articles are allowed free use in scientific and educational applications, with citation of the source.
According to the type of Creative Commons License (CC-BY 4.0) adopted by Ciência & Saúde , the user must respect the requirements below.
You are free to:
Share — copy and redistribute the material in any medium or format.
Adapt — remix, transform, and build upon the material for any purpose, even commercially.
However, only under the following terms:
Attribution — You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests Ciência & Saúde endorses you or your use.
No additional restrictions — You may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.
Notices:
You do not have to comply with the license for elements of the material in the public domain or where your use is permitted by an applicable exception or limitation.
No warranties are given. The license may not give you all of the permissions necessary for your intended use. For example, other rights such as publicity, privacy, or moral rights may limit how you use the material.
For more details on the Creative Commons license, please follow the link in the footer of this website.