Survival and factors associated with mandibular overdenture fractures with immediate loading
DOI:
https://doi.org/10.15448/1980-6523.2018.1.29729Palavras-chave:
dentures, dental prosthesis, dental implants, immediate loading.Resumo
OBJECTIVE: Survival rates of mandibular overdentures on two implants retained by bar-clip system with immediate loading and the factors related to fractures was analyzed.
METHODS: Twenty-three subjects were followed for 32 months. Fracture occurrence was the outcome variable, while the thickness of denture base, maxillomandibular space and masticatory efficiency comprised the independent variables.
RESULTS: The survival rate was 49.5%, with 34.7% of fractures. There was no association between the independent variables and fractures.
CONCLUSION: So, the risk of mandibular overdenture fractures with immediate loading is high. Furthermore, masticatory efficiency, thickness of the denture base and maxillomandibular space did not influence the incidence of fractures.
*** Sobrevida e fatores associados a fraturas de sobredentaduras inferiores com carga imediata ***
OBJETIVO: A taxa de sobrevida de sobredentaduras mandibulares com dois implantes retidas por sistema barra-clipe com carga imediada e os fatores associados a fraturas foram analisados.
METODOLOGIA: Vinte e três indivíduos foram acompanhados por 32 meses. A ocorrência de fratura foi a variável dependente, enquanto a espessura da base da prótese, o espaço maxilomandibular e a eficiência mastigatória compreendeu as variáveis independentes.
RESULTADOS: A taxa de sobrevida foi de 49,5%, com 34,7% de fraturas. Não houve associação entre as variáveis independentes e as fraturas.
CONCLUSÃO: Assim, o risco de fraturas de sobredentadura mandibular com carga imediata é alto. Além disso, a eficiência mastigatória, a espessura da base dentária e o espaço maxilomandibular não influenciaram na incidência de fraturas.
Palavras-chave: dentadura; prótese dentária; implantes dentários; carga imediata.
Referências
Andreiotelli M, Att W, Strub J. Prosthodontic Complications with implants overdentures: a systematic literature review. Int J Prosthodont 2010;23: 195-203.
Fajardo R, Pruitt L, Finzen FC, Marshall GW, Singh S, Curtis DA. The effect of E-glass fibers and acrylic resin thickness on fracture load in a simulated implant-supported overdenture prosthesis. J Prosthet Dent 2011;106: 373-7.
https://doi.org/10.1016/S0022-3913(11)60150-9
Zancope K, Simamoto Júnior PC, Davi LR, Prado CJ, Neves FD. Immediate loading implants with mandibular overdenture: a 48-month prospective follow-up study. Braz Oral Res 2014;28:313-8.
https://doi.org/10.1590/1807-3107BOR-2014.vol28.0030
Vercruyssen M, Marcelis K, Coucke W, Naert I, Quirynen M. Long-term, retrospective evaluation (implant and patient-centred outcome) of the two-implants-supported overdenture in the mandible. Part 1: survival rate.Clin Oral Implants Res 2010;21:357-65.
https://doi.org/10.1111/j.1600-0501.2009.01849.x
Gonda T, Maeda Y, Walton JN, MacEntee MI. Fracture incidence in mandibular overdentures retained by one or two implants. J Prosthet Dent 2010;103:178-81.
https://doi.org/10.1016/S0022-3913(10)60026-1
Cakarer S, Can T, Yaltiric M, Keskin C. Complications associated with the ball, bar and Locator attachments for implant-supported overdentures. Med Oral Patol Oral Cir Bucal 2011;16:953-9.
https://doi.org/10.4317/medoral.17312
Bilhan R, Geckili O, Mumcu E, Bilmenoglu C. Maintenance requirements associated with mandibular implant overdentures: clinical results after first year of service. J Oral Implantol 2011;37:697-704.
https://doi.org/10.1563/AAID-JOI-D-10-00096
Santos CE, Freitas O, Spadaro ACC, Mestriner-Junior W. Development of a colorimetric system for evaluation of the masticatory efficiency. Braz Dent J 2006;17:95-9.
Downloads
Publicado
Edição
Seção
Licença
DIREITOS AUTORAIS
A submissão de originais para a Odonto Ciência implica na transferência, pelos autores, dos direitos de publicação. Os direitos autorais para os artigos publicados nesta revista são do autor, com direitos da revista sobre a primeira publicação. Os autores somente poderão utilizar os mesmos resultados em outras publicações indicando claramente a Odonto Ciência como o meio da publicação original.
LICENÇA CREATIVE COMMONS
Em virtude de ser uma revista de acesso aberto, permite-se o uso gratuito dos artigos em aplicações científicas e educacionais, desde que citada a fonte. De acordo com a Licença Creative Commons CC-BY 4.0, adotada pela Odonto Ciência o usuário deve respeitar os requisitos abaixo.
Você tem o direito de:
Compartilhar — copiar e redistribuir o material em qualquer suporte ou formato.
Adaptar — remixar, transformar e criar a partir do material para qualquer fim, mesmo que comercialmente.
Porém, somente de acordo com os termos seguintes:
Atribuição — Você deve dar o crédito apropriado, prover um link para a licença e indicar se mudanças foram feitas. Você deve fazê-lo em qualquer circunstância razoável, mas de maneira alguma que sugira que a Odonto Ciência apoia você ou o seu uso.
Sem restrições adicionais — Você não pode aplicar termos jurídicos ou medidas de caráter tecnológico que restrinjam legalmente outros de fazerem algo que a licença permita.
Avisos:
Você não tem de cumprir com os termos da licença relativamente a elementos do material que estejam no domínio público ou cuja utilização seja permitida por uma exceção ou limitação que seja aplicável.
Não são dadas quaisquer garantias. A licença pode não lhe dar todas as autorizações necessárias para o uso pretendido. Por exemplo, outros direitos, tais como direitos de imagem, de privacidade ou direitos morais, podem limitar o uso do material.
Para mais detalhes sobre a licença Creative Commons, siga o link no rodapé desta página eletrônica.