The clinical avaluation of the NOVAPEX apex locator in the determining working length in anteriors tooth
Abstract
In endodontic therapy, the correct determination of the working lenght constitutes an important step in repairing the periapical area. This study’s aim is to evaluate the reliability of the apical locator NOVATEX in the determination of the lenght of work, using as parameter the periapical x-ray, effectuated by the technique of bisecting the angle. The sample was composed by 76 anterior canals, both upper and lower. Of those, 26 teeth contained live pulp and 50 teeth contained necrosed pulp. According to the anatomic diameter in the third apical, it was introduced inside the radicular canal a juxtaposed file K to this area, with lenghts of 25 mm or 31 mm, and when the apparel showed the indicative led 1, the teeth were x-rayed in this size. The x-rays were digitalized in a special scanner for x-ray and measured from the top of the instrument to the radiographic apical vertex were determined, with the help of Photoshop 7.0. Measures between 0.5 mm and 2 mm of the apical vertex to the radiographic were considered reliable. The results showed success in 25 measurements (96,2%), in teeth with live vital pulp and 43 measurements (86%), in teeth with necrosed pulp. Of all cases, in 68 measurements (89,5%), the referred locator offered radiographic measurements inside the pre-established parameter. It is than concluded, through the analysis of the results that the apical locator NOVAPEX constitutes in a reliable auxiliary resource in determining the working length.UNITERMS: apex locator; working lenght; NOVAPEX.
Downloads
Published
Issue
Section
License
COPYRIGHT
The submission of originals to Odonto Ciência implies the transfer by the authors of the right for publication. Authors retain copyright and grant the journal right of first publication. If the authors wish to include the same data into another publication, they must cite Odonto Ciência as the site of original publication.
CREATIVE COMMONS LICENSE
As this journal is open access, the articles are allowed free use in scientific and educational applications, with citation of the source.
According to the type of Creative Commons License (CC-BY 4.0) adopted by Odonto Ciência, the user must respect the requirements below.
You are free to:
Share — copy and redistribute the material in any medium or format.
Adapt — remix, transform, and build upon the material for any purpose, even commercially.
However, only under the following terms:
Attribution — You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests Odonto Ciência endorses you or your use.
No additional restrictions — You may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.
Notices:
You do not have to comply with the license for elements of the material in the public domain or where your use is permitted by an applicable exception or limitation.
No warranties are given. The license may not give you all of the permissions necessary for your intended use. For example, other rights such as publicity, privacy, or moral rights may limit how you use the material.
For more details on the Creative Commons license, please follow the link in the footer of this website.