Comparative assessment of the flow rate of root canal sealers

Norberto Batista de Faria-Júnior, Santiago Massi, Hugo Ricardo Croti, José Carlos Rivas Gutierrez, Fábio Roberto Dametto, Luis Geraldo Vaz

Abstract


Purpose: This study evaluated the flow rate of the Acroseal, AH Plus, Endomethasone N, Sealapex, and ActiV GP according to the standards of the ISO specification 6876/2001.
Methods: A volume of 0.05 mL of the cement mixed according to the manufacturer’s recommendations was placed on a glass plate. At 180±5 s after the commencement of mixing, the second glass plate was placed on top of the sealer, followed by the weight of mass approximately 100 g to make a total mass on the plate of 120±2 g. Ten min after the start of mixing, the weight was removed and the value of the diameter of the compressed disc of sealer was measured. The mean of three such determinations for each sealer was taken as the flow of the material. The mean values were compared using ANOVA and Tukey’s tests.
Results: The results obtained were: Acroseal 21.24 mm, AH Plus 22.72 mm, ActiV GP 24.90 mm, Endomethasone N 18.76 mm, and Sealapex 25.15 mm.
Conclusion: Only the Endomethasone N did not conform to ISO Specification that requires that a sealer shall have a diameter of not less than 20 mm. The Sealapex achieved the greatest flow, but it did not differ from Activ GP and AH Plus (P>0.5).

Keywords


Flow; dental materials; root canal sealers

Full Text:

PDF


e-ISSN: 1980-6523

ISSN-L: 0102-9460

 

This journal is a member of, and subscribes to the principles of, the Committee on Publication Ethics (COPE) http://www.publicationethics.org


SJR (SCImago Journal & Country Rank) IMPACT FACTOR:

SCImago Journal & Country Rank

Licença Creative Commons

Except where otherwise noted, content of this journal is licensed under a Creative Commons Attribution 4.0 International license.

 

Editorial Policies of Brazilian Scientific Journals. Deposit availability: Blue .

 

Copyright: © 2006-2019 EDIPUCRS